Industrial Water Chiller for CNC Spindles

S&A / TEYU Industrial Water Chillers for CNC Spindles — closed-loop cooling units with an integrated circulation pump for water-cooled CNC spindles. Choose CW-3000 for passive radiator-and-fan heat dissipation, or CW-5000 / CW-5200 for active compressor refrigeration with controlled coolant temperature. Suitable for CNC routers, engraving machines and other spindle systems requiring reliable continuous cooling.

Price without tax: Price range: 157.30 € through 491.70 €

Add selected () for 0 €
Add selected () for 0 €
Add selected to cart
Filters Sort results
Reset Apply
SKU
Name
Price
Qty
1245001
Chiller-CW-3000-TGTY
157.30 €
Max:
Min: 0
Step: 1
1245002
Chiller-CW-5000-TGTY
448.80 €
Max:
Min: 0
Step: 1
1245003
Chiller-CW-5200-THTY
491.70 €
Out of Stock
Add selected () for 0 €
Add selected () for 0 €
Add selected to cart
Product SKU: 1245000
Back to:

Description

The S&A / TEYU CW-3000, CW-5000 and CW-5200 series provide closed-loop water circulation for CNC spindle cooling. The three models serve different thermal loads: CW-3000 is a thermolysis-type cooler that rejects heat through a radiator and fan, while CW-5000 and CW-5200 use active compressor refrigeration for controlled coolant temperature. This makes the range suitable for CNC routers, engraving machines and other equipment using water-cooled motorized spindles.

For reliable operation, select the model according to the spindle heat load, ambient temperature and required temperature stability rather than spindle power alone. All three models include an integrated circulation pump. For normal operation, use clean distilled, purified or deionized water; a compatible non-corrosive antifreeze coolant may be used when freeze protection is required.

⚠️ Vallder Ltd is a direct importer of this product from the original manufacturer, with guaranteed quality and full support. Beware of cheap imitations sold online — they often lack proper certification and use lower-grade components.

 


CW-3000-TGTY – Passive Heat-Dissipation Cooler

The CW-3000-TGTY circulates coolant through the spindle and removes heat through an air-cooled radiator. It does not use a refrigeration compressor and therefore does not hold the water to a user-set chilled temperature below ambient. The manufacturer specifies a heat-dissipation capacity of 50 W/°C.

ParameterCW-3000-TGTY
VoltageAC 1P 220–240V
Frequency50/60Hz
Current0.4–0.7A
Max. power consumption0.07kW
Heat-dissipation capacity50W/°C
Max. pump pressure1bar
Max. pump flow10L/min
ProtectionFlow alarm
Tank capacity9L
Inlet / outletOD 10mm barbed connector
Net / gross weight9kg / 11kg
Dimensions49 × 27 × 38cm (L × W × H)
Package dimensions55 × 34 × 43cm (L × W × H)
SKU Number1245001

All product data (pictures, dimensions, tables, drawings) are provided as received from the supplier; we exclude liability for their accuracy or completeness.

S&A CW-3000-TGTY industrial water cooler for CNC spindle

S&A CW-3000-TGTY rear view


CW-5000-TGTY – Active Refrigeration Chiller

The CW-5000-TGTY uses compressor refrigeration and electronic temperature control. It is intended where passive heat dissipation is insufficient and a stable coolant temperature is required. The manufacturer specifies approximately 750W nominal cooling capacity and ±0.3°C temperature stability for the CW-5000 family, with constant-temperature and intelligent temperature-control modes.

ParameterCW-5000-TGTY
VoltageAC 1P 220–240V
Frequency50/60Hz
Current0.4–2.8A
Max. power consumption0.4/0.46kW, 0.31/0.37kW
Compressor power0.41/0.49HP, 2559Btu/h, 0.75kW
Nominal cooling capacity644Kcal/h
Pump power0.03kW
Max. pump pressure1bar
Max. pump flow10L/min
RefrigerantR-134a
Temperature stability±0.3°C
ReducerCapillary
Tank capacity6L
Inlet / outletOD 10mm barbed connector
Net / gross weight18kg / 20kg
Dimensions58 × 29 × 47cm (L × W × H)
Package dimensions65 × 36 × 51cm (L × W × H)
SKU Number1245002

All product data (pictures, dimensions, tables, drawings) are provided as received from the supplier; we exclude liability for their accuracy or completeness.

S&A CW-5000-TGTY refrigerated water chiller for CNC spindle

S&A CW-5000-TGTY rear view


CW-5200-THTY – Higher-Capacity Refrigeration Chiller

The CW-5200-THTY is the higher-capacity option in this group. It uses active refrigeration, a circulating pump and electronic control to maintain coolant temperature under higher thermal loads. The manufacturer specifies up to 1430W cooling capacity and ±0.3°C temperature stability for the CW-5200 family.

ParameterCW-5200-THTY
VoltageAC 1P 220–240V
Frequency50/60Hz
Current0.5–4.8A
Max. power consumption0.69/0.83kW, 0.56/0.7kW
Compressor power0.75/0.93HP, 4879Btu/h, 1.43kW
Nominal cooling capacity1229Kcal/h
Pump power0.05kW
Max. pump pressure1.2bar
Max. pump flow13L/min
RefrigerantR-134a
Temperature stability±0.3°C
ReducerCapillary
Tank capacity6L
Inlet / outletOD 10mm barbed connector
Net / gross weight22kg / 25kg
Dimensions58 × 29 × 47cm (L × W × H)
Package dimensions65 × 36 × 51cm (L × W × H)
SKU Number1245003

All product data (pictures, dimensions, tables, drawings) are provided as received from the supplier; we exclude liability for their accuracy or completeness.

S&A CW-5200-THTY industrial water chiller for CNC spindle

S&A CW-5200-THTY rear view


How to Select the Correct Model

ModelCooling methodBest suited toImportant selection point
CW-3000Radiator + fanLower heat loads where coolant may run above ambient50W/°C heat-dissipation rating; no compressor refrigeration
CW-5000Active refrigerationCNC spindle systems requiring controlled coolant temperatureApprox. 750W nominal cooling capacity and ±0.3°C stability
CW-5200Active refrigerationHigher thermal loads and longer continuous operationUp to 1430W cooling capacity and ±0.3°C stability

General family data above is based on current manufacturer documentation; delivered variants and revisions can differ. Always check the model nameplate and supplied manual before commissioning.


Installation and Coolant Recommendations

  • Integrated pump: CW-3000, CW-5000 and CW-5200 all include a built-in circulation pump, so a separate external water pump is not required for the normal cooling loop.
  • Normal coolant: use clean distilled, purified or deionized water. Avoid tap water because minerals and impurities can contaminate or restrict the cooling circuit.
  • Freeze protection: where freezing is possible, a compatible non-corrosive antifreeze coolant may be used according to TEYU guidance. For normal temperatures, distilled/purified water is preferred.
  • Correct circulation: connect chiller outlet to the spindle coolant inlet and spindle outlet back to the chiller inlet.
  • Never run dry: fill the reservoir and confirm circulation before extended operation; dry running can damage the pump.
  • Ventilation: keep air inlet and outlet clear. Restricted airflow reduces heat rejection and may trigger high-temperature alarms.
  • Water level: keep the level within the normal range indicated on the level gauge and inspect periodically for leaks.

 


Cooling Principle

The CW-3000 and CW-5000/CW-5200 use two different cooling principles. The diagrams below show the coolant path and heat-removal method for each system.

CW-3000 passive radiator and fan cooling principle

CW-3000 – Passive Heat Dissipation

The CW-3000 uses its integrated circulation pump to move coolant through the spindle and back through an air-cooled radiator. A fan transfers the absorbed heat from the radiator to the surrounding air. Because there is no refrigeration compressor, the unit dissipates heat relative to ambient temperature rather than actively chilling the coolant to a set temperature.

CW-5000 and CW-5200 active refrigeration cooling principle

CW-5000 / CW-5200 – Active Refrigeration

The CW-5000 and CW-5200 circulate coolant through the spindle and then through an evaporator, where heat is transferred into the refrigerant circuit. The compressor, condenser and fan reject this heat to the ambient air, allowing the electronic controller to maintain a controlled coolant temperature with substantially greater cooling capability than the passive CW-3000 design.


Controls and Maintenance

The refrigerated CW-5000/CW-5200 units provide electronic temperature monitoring and alarm functions. The manufacturer documents constant-temperature and intelligent-control modes, as well as protection for abnormal flow and temperature conditions. Clean ventilation grilles and filter gauze regularly, keep the coolant clean and investigate any flow alarm before continuing operation.

CW-5200 temperature controller

Temperature Controller

Electronic temperature monitoring with configurable control modes on refrigerated models.

CW-5200 water level indicator

Water Level Indicator

Provides a quick visual check of reservoir level before and during operation.

CW-5200 removable dust filter

Dust Filter

Removable side filter supports routine cleaning and unobstructed condenser airflow.

  FAQ frequently asked questions


Do all CW-3000, CW-5000 and CW-5200 models have a built-in circulation pump?

Yes. All three models include an integrated circulation pump that moves coolant through the spindle cooling circuit. Under normal installation, a separate external water pump is not required. Pump flow and pressure differ by model.

Which coolant should I use: distilled water or a special coolant?

For normal operation, TEYU recommends clean distilled, purified or deionized water. A special compatible non-corrosive antifreeze coolant can also be used when freeze protection is required. In other words, both are supported depending on the environment, but distilled/purified water is the preferred normal coolant and antifreeze should be used only when necessary and according to manufacturer guidance.

Is the CW-3000 a refrigerated chiller?

No. CW-3000 is a thermolysis-type circulating cooler. It uses a radiator and fan to reject heat and does not contain a compressor refrigeration circuit.

How often should the coolant be replaced?

TEYU commonly recommends changing circulating water approximately every three months, with shorter intervals in dusty or contaminated working environments.

What does a flow alarm indicate?

It indicates insufficient or interrupted coolant flow. Check the water level, tubing for kinks or blockage, leaks and pump operation before resuming machine operation.

What temperature-control modes are available on CW-5000 and CW-5200?

Manufacturer documentation describes constant-temperature and intelligent-control modes. Use the supplied controller manual for parameter changes because controller revisions can differ.

How much ventilation space is required?

Do not obstruct the air inlet or exhaust. Current CW-5000/CW-5200 installation guidance calls for generous clearance around the ventilation openings; follow the manual supplied with the exact unit.

Can antifreeze be used?

Yes. When freezing conditions cannot be avoided, use a chiller-compatible, non-corrosive antifreeze formulation. TEYU guidance recommends glycol-based antifreeze mixed with purified/deionized water for cold conditions and returning to purified or distilled water when freezing protection is no longer needed.

Why can specifications differ between online documents?

TEYU has produced multiple model revisions and pump/refrigerant configurations. The exact model nameplate and documentation supplied with the delivered unit take precedence over generic family data.

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.