Description
Details
The MDR DIN rail power supply family is designed for compact industrial control cabinets, CNC systems, automation panels and auxiliary DC circuits. In addition to the existing MDR-60 variants, this product now includes the compact MDR-20 series with 5V, 12V and 24V DC outputs. MDR-20 units accept 85–264VAC or 120–370VDC input, mount on standard TS35/7.5 or TS35/15 DIN rail and use free-air convection cooling.
The MDR-20 series combines adjustable DC output, LED power indication, short-circuit, overload and over-voltage protection, plus a built-in DC OK active signal. The 22.5mm housing width makes these models suitable where panel space is limited.
| MODEL | MDR-60-5 | MDR-60-12 | MDR-60-24 | MDR-60-48 | |
| OUTPUT | DC VOLTAGE | 5V | 12V | 24V | 48V |
| RATED CURRENT | 12A | 5A | 2.5A | 1.25A | |
| CURRENT RANGE | 0 ~ 12A | 0 ~ 5A | 0 ~ 2.5A | 0 ~ 1.25A | |
| RATED POWER | 50W | 60W | 60W | 60W | |
| RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |
| VOLTAGE ADJ. RANGE | 5 ~ 6V | 12 ~ 15V | 24 ~ 30V | 48 ~ 56V | |
| VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
| LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
| LOAD REGULATION | ±1.5% | ±1.0% | ±1.0% | ±1.0% | |
| SETUP, RISE TIME Note.5 | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load | ||||
| HOLD UP TIME (Typ.) | 50ms/230VAC 20ms/115VAC at full load | ||||
| INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | |||
| FREQUENCY RANGE | 47 ~ 63Hz | ||||
| EFFICIENCY (Typ.) | 79% | 86% | 88% | 87% | |
| AC CURRENT (Typ.) | 1.8A / 115VAC 1A / 230VAC | ||||
| INRUSH CURRENT (Typ.) | COLD START 30A / 115VAC 60A / 230VAC | ||||
| LEAKAGE CURRENT | <1ma 240vac=”” td=””> | ||||
| PROTECTION | OVERLOAD | 105 ~ 150% rated output power | |||
| Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||
| OVER VOLTAGE | 6.25 ~ 7.25V | 15.6 ~ 18V | 31.2 ~ 36V | 57.6 ~ 64.8V | |
| Protection type : Shut down o/p voltage, re-power on to recover | |||||
| FUNCTION | DC OK SIGNAL | Relay contact rating(max.): 30V / 1A resistive | |||
| ENVIRONMENT | WORKING TEMP. | -20 ~ +70 (Refer to output load derating curve) | |||
| WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
| STORAGE TEMP., HUMIDITY | -40 ~ +85 , 10 ~ 95% RH | ||||
| TEMP. COEFFICIENT | ±0.03% / (0 ~ 50) | ||||
| VIBRATION | Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6 | ||||
| SAFETY & EMC (Note 4) | SAFETY STANDARDS | UL508, TUV EN60950-1 Approved | |||
| WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC 25 70%RH | ||||
| EMI CONDUCTION & RADIATION | Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B | ||||
| HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | ||||
| EMS IMMUNITY | Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3 heavy industry level, criteria A | ||||
| OTHERS | MTBF | 299.2K hrs min. MIL-HDBK-217F (25) | |||
| DIMENSION | 40*90*100mm (W*H*D) | ||||
| PACKING | 0.33Kg; 42pcs / 14.8Kg / 0.82CUFT | ||||
| NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. | ||||
| Pictures, dimensions,table data and technical drawings of this product are made with reasonable care and liability is excluded for the accuracy and correctness of this data. | |||||
MDR-20 Series Technical Data
The table below lists the technical parameters for the three MDR-20 variants available under this product.
| MODEL | MDR-20-5 | MDR-20-12 | MDR-20-24 | |
| OUTPUT | DC VOLTAGE | 5V | 12V | 24V |
| RATED CURRENT | 3A | 1.67A | 1A | |
| CURRENT RANGE | 0 ~ 3A | 0 ~ 1.67A | 0 ~ 1A | |
| RATED POWER | 15W | 20W | 24W | |
| RIPPLE & NOISE (max.) | 80mVp-p | 120mVp-p | 150mVp-p | |
| VOLTAGE ADJ. RANGE | 4.75 ~ 5.5V | 10.8 ~ 13.2V | 21.6 ~ 26.4V | |
| VOLTAGE TOLERANCE | ±2.0% | ±1.0% | ±1.0% | |
| LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | |
| LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | |
| INPUT | VOLTAGE RANGE | 85 ~ 264VAC / 120 ~ 370VDC | ||
| FREQUENCY RANGE | 47 ~ 63Hz | |||
| EFFICIENCY (Typ.) | 76% | 80% | 84% | |
| AC CURRENT (Typ.) | 0.55A / 115VAC 0.35A / 230VAC | |||
| INRUSH CURRENT (Typ.) | Cold start 20A / 115VAC 40A / 230VAC | |||
| LEAKAGE CURRENT | <1mA / 240VAC | |||
| PROTECTION | OVERLOAD | 105 ~ 160% rated output power | ||
| OVERLOAD TYPE | Constant current limiting; automatic recovery after fault removal | |||
| OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | |
| FUNCTION | DC OK ACTIVE SIGNAL (max.) | 3.75 ~ 6V / 50mA | 9 ~ 13.5V / 40mA | 18 ~ 27V / 20mA |
| ENVIRONMENT | WORKING TEMP. | -20 ~ +70°C (refer to derating curve) | ||
| WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
| STORAGE TEMP., HUMIDITY | -40 ~ +85°C, 10 ~ 95% RH | |||
| OTHERS | DIMENSION | 22.5 * 90 * 100mm (W*H*D) | ||
| DIN RAIL | TS35/7.5 or TS35/15 | |||
| All product data (pictures, dimensions, tables, drawings) are provided as received from the supplier; we exclude liability for their accuracy or completeness. | ||||
Features
Features:
- Particularly compact dimensions
- Universal input
- LED indicator for power ON
- Cooling by free air convection
- Adjustable output voltage
- DC OK signal (active signal on MDR-20 series; relay output on MDR-60 series)
- Short-circuit, overload and over-voltage protection
- Simple assembly on DIN rail
Block Diagram

Dimensions