MDR-60/20 DIN Rail Power Supply

Compact DIN rail DC power supply family for industrial control, CNC and automation applications, including MDR-20 and MDR-60 series variants. The MDR-20 models provide 5V/3A (15W), 12V/1.67A (20W) or 24V/1A (24W) outputs, with 85–264VAC / 120–370VDC input, adjustable output voltage, LED power indication, free-air cooling, short-circuit/overload/over-voltage protection and DC OK signalling. Designed for TS35/7.5 or TS35/15 DIN rail installation.

Price without tax: Price range: 11.45 € through 19.52 €

Add selected () for 0 €
Add selected () for 0 €
Add selected to cart
Filters Sort results
Reset Apply
SKU
Name
Price
Qty
1109002
MDR-60-12
19.52 €
Max:
Min: 0
Step: 1
1109001
MDR-60-05
18.94 €
Max:
Min: 0
Step: 1
1109003
MDR-60-24
19.06 €
Max:
Min: 0
Step: 1
1109004
MDR-20-5
11.45 €
Out of Stock
1109005
MDR-20-12
11.45 €
Out of Stock
1109006
MDR-20-24
11.45 €
Out of Stock
Add selected () for 0 €
Add selected () for 0 €
Add selected to cart
Product SKU: 1109000
Back to:

Related Products

Description

 Details


The MDR DIN rail power supply family is designed for compact industrial control cabinets, CNC systems, automation panels and auxiliary DC circuits. In addition to the existing MDR-60 variants, this product now includes the compact MDR-20 series with 5V, 12V and 24V DC outputs. MDR-20 units accept 85–264VAC or 120–370VDC input, mount on standard TS35/7.5 or TS35/15 DIN rail and use free-air convection cooling.

The MDR-20 series combines adjustable DC output, LED power indication, short-circuit, overload and over-voltage protection, plus a built-in DC OK active signal. The 22.5mm housing width makes these models suitable where panel space is limited.

MODELMDR-60-5MDR-60-12MDR-60-24MDR-60-48
OUTPUTDC VOLTAGE5V12V24V48V
RATED CURRENT12A5A2.5A1.25A
CURRENT RANGE0 ~ 12A0 ~ 5A0 ~ 2.5A0 ~ 1.25A
RATED POWER50W60W60W60W
RIPPLE & NOISE (max.) Note.280mVp-p120mVp-p150mVp-p200mVp-p
VOLTAGE ADJ. RANGE5 ~ 6V12 ~ 15V24 ~ 30V48 ~ 56V
VOLTAGE TOLERANCE  Note.3±2.0%±1.0%±1.0%±1.0%
LINE REGULATION±1.0%±1.0%±1.0%±1.0%
LOAD REGULATION±1.5%±1.0%±1.0%±1.0%
SETUP, RISE TIME          Note.5500ms, 30ms/230VAC          500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)50ms/230VAC          20ms/115VAC at full load
INPUTVOLTAGE RANGE85 ~ 264VAC          120 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY (Typ.)79%86%88%87%
AC CURRENT (Typ.)1.8A / 115VAC          1A / 230VAC
INRUSH CURRENT (Typ.)COLD START 30A / 115VAC          60A / 230VAC
LEAKAGE CURRENT<1ma 240vac=”” td=””>
PROTECTIONOVERLOAD105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE6.25 ~ 7.25V15.6 ~ 18V31.2 ~ 36V57.6 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTIONDC OK SIGNALRelay contact rating(max.): 30V / 1A resistive
ENVIRONMENTWORKING TEMP.-20 ~ +70     (Refer to output load derating curve)
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85    , 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%   /     (0 ~ 50)
VIBRATIONComponent : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
SAFETY & EMC
(Note 4)
SAFETY STANDARDSUL508, TUV EN60950-1 Approved
WITHSTAND VOLTAGEI/P-O/P:3KVAC     I/P-FG:1.5KVAC     O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC 25     70%RH
EMI CONDUCTION & RADIATIONCompliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B
HARMONIC CURRENTCompliance to EN61000-3-2,-3
EMS IMMUNITYCompliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3 heavy industry level, criteria A
OTHERSMTBF299.2K hrs min.      MIL-HDBK-217F (25)
DIMENSION40*90*100mm (W*H*D)
PACKING0.33Kg; 42pcs / 14.8Kg / 0.82CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25     of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
Pictures, dimensions,table data and technical drawings of this product are made with reasonable care and liability is excluded for the accuracy and correctness of this data.

MDR-20 Series Technical Data

The table below lists the technical parameters for the three MDR-20 variants available under this product.

MODELMDR-20-5MDR-20-12MDR-20-24
OUTPUTDC VOLTAGE5V12V24V
RATED CURRENT3A1.67A1A
CURRENT RANGE0 ~ 3A0 ~ 1.67A0 ~ 1A
RATED POWER15W20W24W
RIPPLE & NOISE (max.)80mVp-p120mVp-p150mVp-p
VOLTAGE ADJ. RANGE4.75 ~ 5.5V10.8 ~ 13.2V21.6 ~ 26.4V
VOLTAGE TOLERANCE±2.0%±1.0%±1.0%
LINE REGULATION±1.0%±1.0%±1.0%
LOAD REGULATION±1.0%±1.0%±1.0%
INPUTVOLTAGE RANGE85 ~ 264VAC    /    120 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY (Typ.)76%80%84%
AC CURRENT (Typ.)0.55A / 115VAC    0.35A / 230VAC
INRUSH CURRENT (Typ.)Cold start 20A / 115VAC    40A / 230VAC
LEAKAGE CURRENT<1mA / 240VAC
PROTECTIONOVERLOAD105 ~ 160% rated output power
OVERLOAD TYPEConstant current limiting; automatic recovery after fault removal
OVER VOLTAGE5.75 ~ 6.75V13.8 ~ 16.2V27.6 ~ 32.4V
FUNCTIONDC OK ACTIVE SIGNAL (max.)3.75 ~ 6V / 50mA9 ~ 13.5V / 40mA18 ~ 27V / 20mA
ENVIRONMENTWORKING TEMP.-20 ~ +70°C (refer to derating curve)
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85°C, 10 ~ 95% RH
OTHERSDIMENSION22.5 * 90 * 100mm (W*H*D)
DIN RAILTS35/7.5 or TS35/15
All product data (pictures, dimensions, tables, drawings) are provided as received from the supplier; we exclude liability for their accuracy or completeness.

 Features


Features:

  • Particularly compact dimensions
  • Universal input
  • LED indicator for power ON
  • Cooling by free air convection
  • Adjustable output voltage
  • DC OK signal (active signal on MDR-20 series; relay output on MDR-60 series)
  • Short-circuit, overload and over-voltage protection
  • Simple assembly on DIN rail

 Block Diagram


mdr 60 power supply block diagram


 Dimensions


mdr 60 power supply dimensions


 

 

 

 

 

 

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.