MDR-60 DIN Rail Power Supply

Universal and compact DC power supply can be mounted on a DIN Rail. Particularly compact dimensions. Universal input. LED indicator for power ON. Cooling by free air convection. Adjustable output voltage. DC OK signal (Relay output). Short-circuit, overload and over-voltage protection. Simple assembly on DIN rail.

Price without tax:

17.22 17.75 

Add selected () for 0 
Add selected () for 0 
Add selected to cart
Filters Sort results
Reset Apply
SKU
Name
Price
Qty
1109002
MDR-60-12
17.75 
Max:
Min: 0
Step: 1
1109001
MDR-60-05
17.22 
Max:
Min: 0
Step: 1
1109003
MDR-60-24
17.33 
Max:
Min: 0
Step: 1
Related Products

Description

 Details


MODELMDR-60-5MDR-60-12MDR-60-24MDR-60-48
OUTPUTDC VOLTAGE5V12V24V48V
RATED CURRENT12A5A2.5A1.25A
CURRENT RANGE0 ~ 12A0 ~ 5A0 ~ 2.5A0 ~ 1.25A
RATED POWER50W60W60W60W
RIPPLE & NOISE (max.) Note.280mVp-p120mVp-p150mVp-p200mVp-p
VOLTAGE ADJ. RANGE5 ~ 6V12 ~ 15V24 ~ 30V48 ~ 56V
VOLTAGE TOLERANCE  Note.3±2.0%±1.0%±1.0%±1.0%
LINE REGULATION±1.0%±1.0%±1.0%±1.0%
LOAD REGULATION±1.5%±1.0%±1.0%±1.0%
SETUP, RISE TIME          Note.5500ms, 30ms/230VAC          500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)50ms/230VAC          20ms/115VAC at full load
INPUTVOLTAGE RANGE85 ~ 264VAC          120 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY (Typ.)78%86%88%87%
AC CURRENT (Typ.)1.8A / 115VAC          1A / 230VAC
INRUSH CURRENT (Typ.)COLD START 30A / 115VAC          60A / 230VAC
LEAKAGE CURRENT<1ma 240vac=”” td=””>
PROTECTIONOVERLOAD105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE6.25 ~ 7.25V15.6 ~ 18V31.2 ~ 36V57.6 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
FUNCTIONDC OK SIGNALRelay contact rating(max.): 30V / 1A resistive
ENVIRONMENTWORKING TEMP.-20 ~ +70     (Refer to output load derating curve)
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85    , 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%   /     (0 ~ 50)
VIBRATIONComponent : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
SAFETY & EMC
(Note 4)
SAFETY STANDARDSUL508, TUV EN60950-1 Approved
WITHSTAND VOLTAGEI/P-O/P:3KVAC     I/P-FG:1.5KVAC     O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC 25     70%RH
EMI CONDUCTION & RADIATIONCompliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B
HARMONIC CURRENTCompliance to EN61000-3-2,-3
EMS IMMUNITYCompliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3 heavy industry level, criteria A
OTHERSMTBF299.2K hrs min.      MIL-HDBK-217F (25)
DIMENSION40*90*100mm (W*H*D)
PACKING0.33Kg; 42pcs / 14.8Kg / 0.82CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25     of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
Pictures, dimensions,table data and technical drawings of this product are made with reasonable care and liability is excluded for the accuracy and correctness of this data.

 Features


Features:

  • Particularly compact dimensions
  • Universal input
  • LED indicator for power ON
  • Cooling by free air convection
  • Adjustable output voltage
  • DC OK signal (Relay output)
  • Short-circuit, overload and over-voltage protection
  • Simple assembly on DIN rail

 Block Diagram


mdr 60 power supply block diagram


 Dimensions


mdr 60 power supply dimensions


 

 

 

 

 

 

Ask a question

MDR-60 DIN Rail Power Supply

Universal and compact DC power supply can be mounted on a DIN Rail. Particularly compact dimensions. Universal input. LED indicator for power ON. Cooling by free air convection. Adjustable output voltage. DC OK signal (Relay output). Short-circuit, overload and over-voltage protection. Simple assembly on DIN rail.